Описание

  • Auxiliary release on the front
  • With door monitoring contact
  • Plug connector M23 (RC18)
Approach direction Horizontal and vertical Can be adjusted in 90° steps Solenoid operating voltage
  • AC/DC 24 V +10%, -15%
LED function displayThe switch has a function display (2 LEDs, red and green). The LED voltage is same as the solenoid operating voltage. Guard locking type
TX2Open-circuit current principle, guard locking by applying voltage to the solenoid. Release by spring force.
Switching element
ETX CSlow-action switching contact 2 NC / 1 NO + 1 NO (door monitoring contact)
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. The auxiliary release must be sealed to prevent tampering (for example with sealing lacquer).
Housing material Die-cast alloy, cathodically dipped
Weight
Net 0,8 kg
Ambient temperature -20 ... 80 °C
Degree of protection IP65
Mechanical life 1 x 106
Contact material Silver alloy, gold flashed
Switching principle Slow-action switching contact
Installation orientation Any
Number of door position NO contacts 1
Number of guard lock monitoring positively driven contacts 2
Number of guard lock monitoring NO contacts 1
Connection
1 x Plug connector RC18
Approach speed
max. 20 m/min
Actuation frequency 1200 1/h
Guard locking principle Open-circuit current principle
Locking force Fmax 1700 N
Locking force FZh 1300 N
Retention force 20 N
Extraction force 35 N
Actuating force 35 N
Insertion depth min.32 mm
Electrical connection ratings
Thermal rated current Ith 4 A 70°C => 2A'>
Utilization category according to EN 60947-5-1
AC-15 4A 24V 70°C => 2A'>
DC-13 4A 24V 70°C => 2A'>
Solenoid operating voltage
AC/DC 24 V -15% ... +10%
Short circuit protection according to IEC 60269-1
(Fuse) 4A gG 70°C => 2A gG'>
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 1,5 kV
Switching voltage
Min. at 10mA 12 V
Switching current
Min. at 24V 1 mA
Power consumption 8 W
Solenoid duty cycle 100 %
LED indicator Operating voltage corresponds to the solenoid voltage
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position
B10D 6 x 106
In combination with Actuator BETAETIGER-X-GNQMechanical values and environment
Overtravel 8 mm
In combination with Actuator BETAETIGER-X-GQMechanical values and environment
Overtravel 1 mm
''